Model Number: | 2056 |
MOQ: | 1pcs |
Price: | as the request |
Packaging Details: | 1pcs / bag |
Payment Terms: | Western Union, T/T, |
Compatible radical 7 / 8 spo2 adapter cable extension cable with 20pin for original 2365 / 2055 / 2056/ 2057
Original Red LNCS 20 pin Adapter Cable LNC-01 (2365), LNC-04 (2055), LNC-10 (2056), LNC-14 (2057) for use with LNCS sensors. This adapter cable is for use exclusively with monitors Radical-7, Rad-87, Rad-57 and Pronto-7. For all other monitors with technology, you can use the SpO2 adapter cable 1814.
Main Technical Parameters : 1) Emitted light wavelength: 660±5nm, Absorbed light wavelength: 905±5nm
2) SpO2 test range: 70%-100%;
SpO2 measurement accuracy:
±1% in 90%~100%, ±2% in 80%~89%, ±3% in 70%~79%.
3) Range of pulse rate : 30bpm~245bpm
Measurement accuracy of pulse rate:
±1bpm for 30bpm~59bpm, ±2bpm for 60 bpm~149bpm, ±3bpm for 150bpm~245bpm
Working Environment Requirements: Temperature:5℃~40℃; Relative humidity:≤80%; Air pressure:700hPa~1060hPa
Intended Use: TJ SpO2 sensor is suitable for adult patient (weight >40kg), pediatric patient (weight:10-40kg) to conduct a spot check or continuous noninvasive measurement of arterial oxygen saturation and pulse rate.
Process flow
1.Wire cutting -- 2.Sheath Stripping -- 3.Shield Twisting -- 4.Sleeve Crimping -- 5.Tin soldering -- 6.End Pressing -- 7.Set Plastic Shell -- 8.Electrical Test -- 9.Internal Mold Forming -- 10.Outer Mold Forming -- 11.Visual Inspection -- 12.Electrical Test -- 13.Thread end of network -- 14.Sheath tripping -- 15.Shield twisting -- 16.Tin soldering -- 17.Chips welding -- 18.Glue dispensing --19.Assembly -- 20.Final test -- 21.Package
Model Number: | 2056 |
MOQ: | 1pcs |
Price: | as the request |
Packaging Details: | 1pcs / bag |
Payment Terms: | Western Union, T/T, |
Compatible radical 7 / 8 spo2 adapter cable extension cable with 20pin for original 2365 / 2055 / 2056/ 2057
Original Red LNCS 20 pin Adapter Cable LNC-01 (2365), LNC-04 (2055), LNC-10 (2056), LNC-14 (2057) for use with LNCS sensors. This adapter cable is for use exclusively with monitors Radical-7, Rad-87, Rad-57 and Pronto-7. For all other monitors with technology, you can use the SpO2 adapter cable 1814.
Main Technical Parameters : 1) Emitted light wavelength: 660±5nm, Absorbed light wavelength: 905±5nm
2) SpO2 test range: 70%-100%;
SpO2 measurement accuracy:
±1% in 90%~100%, ±2% in 80%~89%, ±3% in 70%~79%.
3) Range of pulse rate : 30bpm~245bpm
Measurement accuracy of pulse rate:
±1bpm for 30bpm~59bpm, ±2bpm for 60 bpm~149bpm, ±3bpm for 150bpm~245bpm
Working Environment Requirements: Temperature:5℃~40℃; Relative humidity:≤80%; Air pressure:700hPa~1060hPa
Intended Use: TJ SpO2 sensor is suitable for adult patient (weight >40kg), pediatric patient (weight:10-40kg) to conduct a spot check or continuous noninvasive measurement of arterial oxygen saturation and pulse rate.
Process flow
1.Wire cutting -- 2.Sheath Stripping -- 3.Shield Twisting -- 4.Sleeve Crimping -- 5.Tin soldering -- 6.End Pressing -- 7.Set Plastic Shell -- 8.Electrical Test -- 9.Internal Mold Forming -- 10.Outer Mold Forming -- 11.Visual Inspection -- 12.Electrical Test -- 13.Thread end of network -- 14.Sheath tripping -- 15.Shield twisting -- 16.Tin soldering -- 17.Chips welding -- 18.Glue dispensing --19.Assembly -- 20.Final test -- 21.Package