Send Message
Home > products > Ventilator Accessories >
Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE

Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE

Nihon Kohden EtCO2 Sensor

Mainstream EtCO2 Sensor

Place of Origin:

China

Brand Name:

Nihon Kohden

Certification:

CE

Contact Us
Request A Quote
Product Details
Stock:
Yes
Material:
Metal, Plastic
Classfication:
Class II
Warranty:
1 Year
Power Source:
Electric
Payment & Shipping Terms
Minimum Order Quantity
1 carton
Price
as discussed
Packaging Details
1pcs / bag
Delivery Time
2-3 days
Payment Terms
T/T, Western Union
Supply Ability
1000pcs / day
Product Description

Medical equipment Mainstream Nihon Kohden EtCO2 Sensor

 

product description

Item
Value
Vailable Brand
Nihon Kohden
MOQ
1PCS
Color
Grey
Sample
Provide sample
Service
ODM/OEM

 

Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE 0

Medical Equipment Mainstream Nihon Kohden EtCO2 Sensor With CE 1

Specification

Sample Flow Rate
Range:50-150 ml/min; Accuracy:±20% ; Default: 75 ml/min
Principle of Operation
Non-dispersive infrared, dual wavelength, no moving parts
Initialization Time
Capnogram displayed in less than 4 seconds, at an ambient temperature of 25℃, full specifications within 2 mintues
CO2 measurement Range
0-114 mmHg ; 0-15% ; 0-15.2 kPa
CO2 Response Time
Includes Transport time and rise time.Less than 2 seconds, at 150 ml/min sampling flow
Less than 3 seconds, at 100 ml/min sampling flow
Less than 4 seconds, at 50 ml/min sampling flow
CO2 Resolution
0.2 mmHg @ 0-59 mmHg ; 0.5mmHg @60-114 mmHg
CO2 Accuracy
0-40 mmHg ± 2 mmHg41-70 mmHg ± 5% of reading
71-100 mmHg ± 8% of reading
101-114 mmHg ±10% of reading
Above 80 reaths per mintue ±12% of reading
* Note:Gas temperature at 25℃
CO2 Stability
Short Term Drift : Drift over three hours shall not exceed 1 mmHg maximumLong term Drift : Accuracy specification will be
maintained over a six hour period
CO2 Noise
RMS noise of the sensor shall be less than or equal to 0.5 mmHg at 5% CO2
Sampling Rate
100Hz
Respiration Rate Range
2 to 150 breaths per minute
Respiration Rate Accuracy
± 1 breath
Calibration
No Routine user calibration required
EtCO2 Calcuation
Method: peak of the expired CO2 waveform
Inspired CO2 Measurement
Method: Lowest reading of the CO2 waveform in the previous 20 seconds
Temperature
Operation : 0 to 40℃ ; Storage :-40 to 70℃ ; Transport :-40 to 70℃
Humidity
Operation :10 to 90 % RH, Non-condensing ; Storage :10 to 90 % RH, Non-condensing.
Transport: 10 to 90 % RH, Non-condensing.
Atmospheric Perssure
Operating :400-800 mmHg ; Storage :400-800 mmHg ; Transport :400-800 mmHg
Water Resisitance
IPX4-Splash-Proof- sensor only
Voltage Requirements
5 VDC ±5% ; Ripple not to exceed 100.0mV
Power Raing
< 1.2W Typical; < 2.0 W Warm-up
Sensor Weight
< 250 g
Sensor Size
Deep*Wide*High 102*62*38mm
Cable Length
75cm

 

 

Characteristics:
 

Long-term stability, non-dispersive infrared technology with two wavebands
Long service life, infrared black body light source with MEMS
Accurate Results, with built-in temperature, atmospheric pressure, compensation algorithm for the balance gas
Calibration-free, patented calibration algorithm without the need for calibration
Low sampling flow rate, the minimum sampling flow rate 50ml/min
Easy to operate, plug-in measure
Low cost in usage and storage
Specification
Respiration rate range: 2~150 breath/minute
Electric power supply: DC 5V
Power Consumption: 1.2W
Usage Environment: 0~40ºC, 10~90% RH, without condensation
Storage Environment: -40~70ºC, <90% RH, without condensation

Send your inquiry directly to us

Privacy Policy China Good Quality Disposable Spo2 Sensor Supplier. Copyright © 2017-2024 disposablespo2sensor.com . All Rights Reserved.