Brand Name: | mindray |
Model Number: | MEC1000 |
MOQ: | 1pcs |
Packaging Details: | 1pcs / bag |
Payment Terms: | T/T, Western Union, |
Compatible Mindray MEC1000 adult spo2 sensor probe suit for PM9000 / 8000 spo2 cables
Product Description
This compatible sensor connects directly to the bedside monitor. It works with the following patient monitors: Datascope Duo, Trio and Datascope Passport XG, DPM1, DPM2, DPM3, DPM4, DPM5, DPM6, DPM7; ARI 800B; Advanced PM1000F; CRC Medical Health; Goldway, Contec; Danatech;
Mindray: PM 600, PM 6000 (New), PM 7000, 6201, PM 8000, PM 9000, PM 9000 Express, MEC 100, MEC 200, MEC 1000, MEC 1200, MEC 2000, 809B, VS 800;
Kontron: 7138, 7840, 7845;
Medec: MEDEC-1000, M-1000, M-1100;
Creative: PC9000, UP6000; Edan: M3, M3A, M3B, M8, M8A, M8B, M9, M9A, M50, M80, iM8, iM8A, iM8B, iM9, iM9A, iM50, iM80 without OXI technology; Penlon InterMed PM-8000. 9-foot cable.
Compatible sensors are available for the following Datascope OEM part numbers:
1. Description: Mindray Spo2 Sensor, L=3m,
2. Connector Guide: Redel 6-Pins
3. Compatibility: 509B, MEC-1000, MEC-1200, New PM6000, PM7000, PM8000, PM9000, VS800, PM600, PM9000 Express(Mindray tech)
4. Types: Adult finger clip SpO2 sensor, Adult Silicone Soft Rubber SpO2 sensor, Pediatric Clip SpO2 sensor, Pediatric Silicone SpO2 sensor, Neonate Wrap SpO2 sensor, Neonate Y type SpO2 sensor, Adult Ear Clip SpO2 sensor, Animal ear clip SpO2 sensor;
5. Related Products: Extension Cable, ECG Cable with leadwires, IBP Cable, Disposable Transduer, NIBP Cuff, NIBP Tube, Temperatrue Probe.
Emitting light waven length | 660±5nm |
Absorbed light wavelength | 905±5nm or 940±5nm |
SpO2 testing range | 70%-100% |
SpO2 testing precision | ±1% in 90%~100% |
±2% in 80%~89% | |
±3% in 70%~79% | |
Testing range of pulse velocity | 30bpm~245bpm |
Testing precision of pulse velocity | 30bpm~59bpm,±1bpm |
60bpm~149bpm,±2bpm | |
150bpm~245bpm,±3bpm | |
Working environment requirements | |
Environment temperature | 5°C~40°C |
Relative humidity | ≤80% |
Atmospheric pressure | 700hPa~1060hPa |
Customer feedback
“Everything is perfect and couldn’t be happier with the products. Products and customer service are always top notch. I always know I am getting a dependable product.”
Brand Name: | mindray |
Model Number: | MEC1000 |
MOQ: | 1pcs |
Packaging Details: | 1pcs / bag |
Payment Terms: | T/T, Western Union, |
Compatible Mindray MEC1000 adult spo2 sensor probe suit for PM9000 / 8000 spo2 cables
Product Description
This compatible sensor connects directly to the bedside monitor. It works with the following patient monitors: Datascope Duo, Trio and Datascope Passport XG, DPM1, DPM2, DPM3, DPM4, DPM5, DPM6, DPM7; ARI 800B; Advanced PM1000F; CRC Medical Health; Goldway, Contec; Danatech;
Mindray: PM 600, PM 6000 (New), PM 7000, 6201, PM 8000, PM 9000, PM 9000 Express, MEC 100, MEC 200, MEC 1000, MEC 1200, MEC 2000, 809B, VS 800;
Kontron: 7138, 7840, 7845;
Medec: MEDEC-1000, M-1000, M-1100;
Creative: PC9000, UP6000; Edan: M3, M3A, M3B, M8, M8A, M8B, M9, M9A, M50, M80, iM8, iM8A, iM8B, iM9, iM9A, iM50, iM80 without OXI technology; Penlon InterMed PM-8000. 9-foot cable.
Compatible sensors are available for the following Datascope OEM part numbers:
1. Description: Mindray Spo2 Sensor, L=3m,
2. Connector Guide: Redel 6-Pins
3. Compatibility: 509B, MEC-1000, MEC-1200, New PM6000, PM7000, PM8000, PM9000, VS800, PM600, PM9000 Express(Mindray tech)
4. Types: Adult finger clip SpO2 sensor, Adult Silicone Soft Rubber SpO2 sensor, Pediatric Clip SpO2 sensor, Pediatric Silicone SpO2 sensor, Neonate Wrap SpO2 sensor, Neonate Y type SpO2 sensor, Adult Ear Clip SpO2 sensor, Animal ear clip SpO2 sensor;
5. Related Products: Extension Cable, ECG Cable with leadwires, IBP Cable, Disposable Transduer, NIBP Cuff, NIBP Tube, Temperatrue Probe.
Emitting light waven length | 660±5nm |
Absorbed light wavelength | 905±5nm or 940±5nm |
SpO2 testing range | 70%-100% |
SpO2 testing precision | ±1% in 90%~100% |
±2% in 80%~89% | |
±3% in 70%~79% | |
Testing range of pulse velocity | 30bpm~245bpm |
Testing precision of pulse velocity | 30bpm~59bpm,±1bpm |
60bpm~149bpm,±2bpm | |
150bpm~245bpm,±3bpm | |
Working environment requirements | |
Environment temperature | 5°C~40°C |
Relative humidity | ≤80% |
Atmospheric pressure | 700hPa~1060hPa |
Customer feedback