Model Number: | N200 |
MOQ: | 1pcs |
Price: | according to the quantity |
Packaging Details: | 1pcs/bag |
Payment Terms: | T / T, Western Union, , |
7 Pin Non OXI Pulse Oximeter Sensor Finger Clip Adult Patient Suit
N200 7pin non-OXI adult finger clip spo2 sensor, reusable spo2 sensor
Cable Color | Gray |
Cable Material | TPU Jacket |
Category | SpO2 Sensor probe |
Certifications | CE/ISO |
Connector Distal | Male 7-Pin D-Sub Connector |
Connector Proximal | Adult Clip |
Latex-free | Yes |
Packaging Type | Bag |
Packaging Unit | 1 |
Patient Size | Adult (>40Kg) |
SpO2 Technology | OxiSmart |
Total Cable Length | 0.9m |
Warranty | 12 months |
Reminder:
when you select the pulse oximeter probe Spo2 sensor, please check carefully the below points:
1) whether the Spo2 sensor connector is really compatible to your patient monitor socket,such as 5pin or 6pin.
2)whether the patient terminal is the right type you want? Snap or clip?
the probe is used for the right people? such as for adult or neonate.
Manufacturer | Model |
---|---|
Analogic | Lifegard II |
Artema SW | Diascope |
Bionet | BM3, BM3 Plus |
Bionics | BPM-200 |
Biosys | BPM-200, SENTRY |
ChoiceMMed | MD300K1 |
Covidien > | N-10, N-100, N-180, N-190, N-20, N-200, N-30, N-3000, N-390, N-395, N-6000, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, Symphony N-3000 |
Datex Ohmeda | 510, enGuard CM5 |
Draeger | Cicero, Infinity Delta XL, Infinity Gamma XL, Infinity Kappa, Infinity Vista, Narkomed, Narkomed 4, Narkomed 6400, SC 6000, SC 7000, SC 8000, SC 9000XL, Vitalert 1000 |
Edan | H100B, IT500 |
GE Healthcare > Corometrics | 118, 120, 129, 188, 510, 511, 556 |
GE Healthcare > Critikon > Dinamap | 1000, 3000, 9710, 9720, Compact, Dinamap Select, M-NSAT Modules, MPS, Oxyshuttle, Plus, Pro 1000, Pro 300, Pro 300/400, Pro 300/400 (sin- OXI), Pro 400, Pro Series, ProCare, SMU, SMV, SOLAR Series, TRAM Modular x50SL Series |
GE Healthcare > Marquette | Cardioserv, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle 1000, Eagle 4000, Eagle Series, Hellige Eagle, Hellige Eagle 1000, Hellige SMK, MAC 1200, Procare B40, Solar 8000, Solar 8000M, Tram 451, i/9500 |
Goldway | UT4000Apro, UT4000C, UT4000E, UT4000F, UT4000F Pro, UT6000A, Vet 420A |
Huntleigh | SC1000 |
Infinium | Infitron II |
Invivo | 4500 Plus, 4500 Plus 3, Escort 100 OPT11A, Escort 300A, Escort II OPT30, M12, M12 ( SpO2), Millennia, Millennia 4500 Plus 2, Omega 1445, Omni-Trak TVS, Prism ( SpO2), Sat Scout |
Ivy Biomedical | 405A, 405D, 405P, 405T, Vital-Guard 450 CN |
Lumeon | Hand-held Oximeter |
> Physio Control | Lifepak 12 |
Mennen | Envoy, Horizon XL ( SpO2), MR 1300, MR 1300 Mercury, MR 1300 Mercury 1200, Mercury 1200 |
Mindray > Datascope | 3000, Accutorr Plus, Accutorr V, DPM Central Station, DPM1, DPM2, DPM3, DPM4, DPM5, DPM6, DPM7, Duo, Expert, PM-50, PM-60, PM-60Vet, Passport, Passport 2, Passport V, Passport XG, Spectrum, Trio, VS 800, VS 900 |
Nihon Kohden | BSM-1102 Life Scope EC, BSM-2300, BSM-2304 iPro (Life Scope i), BSM-4100, BSM-4102 Procyon LT (Life Scope P), BSM-4104 Procyon (Life Scope P), BSM-4104A, BSM-4112 Procyon LT (Life Scope P), BSM-4114 Procyon (Life Scope P), BSM-4114A, BSM-5100, BSM-9510 Life Scope M ( SpO2), OGS-2000 PocketCare ( SpO2) |
Omron > Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, Press-Mate |
PaceTech | Vitalmax 800 Series (black SpO2) |
HP | 78352C, 78354C, 78834C, 862108, 862231, 862439, 862474, 862478, 863063, 863069, 863073, 863077, 863266, C1, CMS, M1020A, M1020B, M1025B, M1205A, M1350B, M1350C, M1722A, M1722A/B, M1722B, M1732A, M1732A/B, M1732B, M2475B, M2600A, M2601A, M2703A, M2704A, M2705A, M3000A, M3001A, M3002A, M3500B, M3535A, M3536A, M3926A, M3927A, M3928A, M3929A, M4735A, M8102A, M8105A, M8105AS, M8105AT, MCMS, Merlin Systems, V24, V26, Viridia A1, Viridia A3 |
Riester | ri-vital and others |
Siemens | Sirecust 630, Sirecust 700, Sirem SpO2 Module |
Smiths Medical > BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Autocorr, Mini Torr, Mini Torr Plus |
Spacelabs | 90351-0/6, 90465 ( SpO2), 90466 ( SpO2), 90467 ( SpO2), 90489 ( SpO2), 90496 / 90369 / 90367 Ultraview ( SpO2), 90651A-08, 93300, IM77 |
Suntech | all models including NIBP 247B |
Welch Allyn | Atlas ( SpO2), Atlas 6200 Series, Encore, Micropaq ( SpO2), Propaq 106-EL, Propaq 202-EL, Propaq 204-EL, Propaq 206-EL, Propaq CS ( SpO2), Spot Vital Signs, Vital Signs (non-Oxi-Max), Vital Signs (without OXI) |
Other different type for the N100,N200 Spo2 sensor
7pin adult soft tip spo2 sensor
7pin pediatric finger clip spo2 sensor
7pin pediatric soft tip spo2 sensor
7pin neonate wrap spo2 sensor
7pin Multilink Y type spo2 sensor
7pin ear clip spo2 sensor
7pin veterniary clip spo2 sensor
Working Condition:
A.Environment temperature: 5°C~40°C
B.Relative humidity: 0%-80%
C.Atmospheric pressure: 700-1060 hPa
D.Power: 5V( ±10%)
All kinds of Spo2 Sensors for different brands
Main technical parameters:
Main technical parameters | |
Emitting light waven length | 660±5nm |
Absorbed light wavelength | 905±5nm or 940±5nm |
SpO2 testing range | 70%-100% |
SpO2 testing precision | ±1% in 90%~100% |
±2% in 80%~89% | |
±3% in 70%~79% | |
Testing range of pulse velocity | 30bpm~245bpm |
Testing precision of pulse velocity | 30bpm~59bpm,±1bpm |
60bpm~149bpm,±2bpm | |
150bpm~245bpm,±3bpm | |
Working environment requirements | |
Environment temperature | 5°C~40°C |
Relative humidity | ≤80% |
Atmospheric pressure | 700hPa~1060hPa |
every pulse oximeter probes will be inspected to confirm it has good performance.
Model Number: | N200 |
MOQ: | 1pcs |
Price: | according to the quantity |
Packaging Details: | 1pcs/bag |
Payment Terms: | T / T, Western Union, , |
7 Pin Non OXI Pulse Oximeter Sensor Finger Clip Adult Patient Suit
N200 7pin non-OXI adult finger clip spo2 sensor, reusable spo2 sensor
Cable Color | Gray |
Cable Material | TPU Jacket |
Category | SpO2 Sensor probe |
Certifications | CE/ISO |
Connector Distal | Male 7-Pin D-Sub Connector |
Connector Proximal | Adult Clip |
Latex-free | Yes |
Packaging Type | Bag |
Packaging Unit | 1 |
Patient Size | Adult (>40Kg) |
SpO2 Technology | OxiSmart |
Total Cable Length | 0.9m |
Warranty | 12 months |
Reminder:
when you select the pulse oximeter probe Spo2 sensor, please check carefully the below points:
1) whether the Spo2 sensor connector is really compatible to your patient monitor socket,such as 5pin or 6pin.
2)whether the patient terminal is the right type you want? Snap or clip?
the probe is used for the right people? such as for adult or neonate.
Manufacturer | Model |
---|---|
Analogic | Lifegard II |
Artema SW | Diascope |
Bionet | BM3, BM3 Plus |
Bionics | BPM-200 |
Biosys | BPM-200, SENTRY |
ChoiceMMed | MD300K1 |
Covidien > | N-10, N-100, N-180, N-190, N-20, N-200, N-30, N-3000, N-390, N-395, N-6000, NPB-190, NPB-195, NPB-290, NPB-295, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, Symphony N-3000 |
Datex Ohmeda | 510, enGuard CM5 |
Draeger | Cicero, Infinity Delta XL, Infinity Gamma XL, Infinity Kappa, Infinity Vista, Narkomed, Narkomed 4, Narkomed 6400, SC 6000, SC 7000, SC 8000, SC 9000XL, Vitalert 1000 |
Edan | H100B, IT500 |
GE Healthcare > Corometrics | 118, 120, 129, 188, 510, 511, 556 |
GE Healthcare > Critikon > Dinamap | 1000, 3000, 9710, 9720, Compact, Dinamap Select, M-NSAT Modules, MPS, Oxyshuttle, Plus, Pro 1000, Pro 300, Pro 300/400, Pro 300/400 (sin- OXI), Pro 400, Pro Series, ProCare, SMU, SMV, SOLAR Series, TRAM Modular x50SL Series |
GE Healthcare > Marquette | Cardioserv, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Dash Series, Eagle 1000, Eagle 4000, Eagle Series, Hellige Eagle, Hellige Eagle 1000, Hellige SMK, MAC 1200, Procare B40, Solar 8000, Solar 8000M, Tram 451, i/9500 |
Goldway | UT4000Apro, UT4000C, UT4000E, UT4000F, UT4000F Pro, UT6000A, Vet 420A |
Huntleigh | SC1000 |
Infinium | Infitron II |
Invivo | 4500 Plus, 4500 Plus 3, Escort 100 OPT11A, Escort 300A, Escort II OPT30, M12, M12 ( SpO2), Millennia, Millennia 4500 Plus 2, Omega 1445, Omni-Trak TVS, Prism ( SpO2), Sat Scout |
Ivy Biomedical | 405A, 405D, 405P, 405T, Vital-Guard 450 CN |
Lumeon | Hand-held Oximeter |
> Physio Control | Lifepak 12 |
Mennen | Envoy, Horizon XL ( SpO2), MR 1300, MR 1300 Mercury, MR 1300 Mercury 1200, Mercury 1200 |
Mindray > Datascope | 3000, Accutorr Plus, Accutorr V, DPM Central Station, DPM1, DPM2, DPM3, DPM4, DPM5, DPM6, DPM7, Duo, Expert, PM-50, PM-60, PM-60Vet, Passport, Passport 2, Passport V, Passport XG, Spectrum, Trio, VS 800, VS 900 |
Nihon Kohden | BSM-1102 Life Scope EC, BSM-2300, BSM-2304 iPro (Life Scope i), BSM-4100, BSM-4102 Procyon LT (Life Scope P), BSM-4104 Procyon (Life Scope P), BSM-4104A, BSM-4112 Procyon LT (Life Scope P), BSM-4114 Procyon (Life Scope P), BSM-4114A, BSM-5100, BSM-9510 Life Scope M ( SpO2), OGS-2000 PocketCare ( SpO2) |
Omron > Colin | BP-306, BP-508, BP-808, BP-88, BP-88S, Press-Mate |
PaceTech | Vitalmax 800 Series (black SpO2) |
HP | 78352C, 78354C, 78834C, 862108, 862231, 862439, 862474, 862478, 863063, 863069, 863073, 863077, 863266, C1, CMS, M1020A, M1020B, M1025B, M1205A, M1350B, M1350C, M1722A, M1722A/B, M1722B, M1732A, M1732A/B, M1732B, M2475B, M2600A, M2601A, M2703A, M2704A, M2705A, M3000A, M3001A, M3002A, M3500B, M3535A, M3536A, M3926A, M3927A, M3928A, M3929A, M4735A, M8102A, M8105A, M8105AS, M8105AT, MCMS, Merlin Systems, V24, V26, Viridia A1, Viridia A3 |
Riester | ri-vital and others |
Siemens | Sirecust 630, Sirecust 700, Sirem SpO2 Module |
Smiths Medical > BCI | 3100, 3101, 3180, 3300, 3301, 3302, 3303, 3304, 3401, 6100, 9100, Advisor, Autocorr, Mini Torr, Mini Torr Plus |
Spacelabs | 90351-0/6, 90465 ( SpO2), 90466 ( SpO2), 90467 ( SpO2), 90489 ( SpO2), 90496 / 90369 / 90367 Ultraview ( SpO2), 90651A-08, 93300, IM77 |
Suntech | all models including NIBP 247B |
Welch Allyn | Atlas ( SpO2), Atlas 6200 Series, Encore, Micropaq ( SpO2), Propaq 106-EL, Propaq 202-EL, Propaq 204-EL, Propaq 206-EL, Propaq CS ( SpO2), Spot Vital Signs, Vital Signs (non-Oxi-Max), Vital Signs (without OXI) |
Other different type for the N100,N200 Spo2 sensor
7pin adult soft tip spo2 sensor
7pin pediatric finger clip spo2 sensor
7pin pediatric soft tip spo2 sensor
7pin neonate wrap spo2 sensor
7pin Multilink Y type spo2 sensor
7pin ear clip spo2 sensor
7pin veterniary clip spo2 sensor
Working Condition:
A.Environment temperature: 5°C~40°C
B.Relative humidity: 0%-80%
C.Atmospheric pressure: 700-1060 hPa
D.Power: 5V( ±10%)
All kinds of Spo2 Sensors for different brands
Main technical parameters:
Main technical parameters | |
Emitting light waven length | 660±5nm |
Absorbed light wavelength | 905±5nm or 940±5nm |
SpO2 testing range | 70%-100% |
SpO2 testing precision | ±1% in 90%~100% |
±2% in 80%~89% | |
±3% in 70%~79% | |
Testing range of pulse velocity | 30bpm~245bpm |
Testing precision of pulse velocity | 30bpm~59bpm,±1bpm |
60bpm~149bpm,±2bpm | |
150bpm~245bpm,±3bpm | |
Working environment requirements | |
Environment temperature | 5°C~40°C |
Relative humidity | ≤80% |
Atmospheric pressure | 700hPa~1060hPa |
every pulse oximeter probes will be inspected to confirm it has good performance.